Fault Reasons:
1. The voltage of PV string exceeds the inverter max allowed input voltage;
2. Inverter control board is operating abnormal.
1. Use a multi-meter to measure the voltage of the PV panels to see if it exceeds the inverter max allowed input voltage;
2. Reduce the solar panels in each PV string moderately to make sure it's within the inverter max allowed input voltage;
3. If the measured PV string voltage is within the range but this fault still exists, please contact sunways after-sales team at service@sunways-tech.com or +86 400 9922 958 for help.