Sunways Inverter FAQs & Troubleshooting

Find help with Sunways hybrid and grid-tied inverters, batteries, accessories and monitoring. Choose a category below to look up a fault message or support topic. For instructions specific to your product, check the matching user manual or contact technical support.

Hybrid Inverter FAQs

Find the message shown on your inverter below. Fault names and the checks required can vary by model; use the matching user manual when deciding what to do next.

“Mains Lost” indicates that the inverter is not detecting the AC grid supply. Check whether there is a power outage at the property and note whether other electrical equipment has also lost power. If the grid supply is available but the message remains, ask your installer to check the AC supply path and connections using the manual for your inverter.

“Grid Voltage Fault” indicates that the detected grid voltage is outside the configured protection range. Record the message, the displayed reading and when it occurs. Ask your installer to check the local supply, AC installation and approved settings for your exact model and installation location. Do not change the country profile or widen protection limits to clear the alarm.

“Grid Frequency Fault” indicates that the detected grid frequency is outside the configured protection range. Record whether the message coincides with a grid disturbance. If it remains or returns, ask your installer to verify the supply and the correct installation-country settings. Changing to a different country profile is not a general troubleshooting step.

“DCI Fault” relates to the DC component detected in the inverter’s AC output. Record the exact message and contact your installer if it persists. Any restart or diagnostic procedure should follow the user manual for your exact model; do not use a restart sequence from a different inverter.

“ISO Over Limitation” indicates that the inverter has detected low insulation resistance. Note whether the message appears during wet weather or after work on the installation. Ask a qualified installer to inspect the relevant wiring and insulation according to the model’s manual. Do not disconnect PV strings or carry out electrical measurements yourself.

“GFCI Fault” indicates that the inverter has detected excessive leakage current. Record when the alarm appears and whether weather conditions or recent installation work coincide with it. Ask your installer to investigate the insulation and relevant circuits. Weather-related timing alone does not confirm the cause or show that the installation is safe.

“PV Over Voltage” indicates that the inverter has detected a PV input voltage above its permitted limit. Ask your installer to compare the PV string design and measurements with the datasheet and user manual for the exact inverter model. Do not remove panels or disconnect PV connectors yourself.

“Bus Voltage Fault” concerns the inverter’s internal DC bus voltage. The fault message alone does not establish whether the cause is the PV input or an internal issue. Record the message and ask your installer or Sunways technical support to identify the checks required for your exact model.

“Inverter Over Temperature” indicates that the inverter has detected an excessive internal temperature. From a safe position, check whether its ventilation area is visibly obstructed and note the surrounding conditions. Ask your installer to verify the installation clearances and cooling requirements in the correct user manual. Contact support if the alarm persists.

Record “SPI Fault” exactly as displayed, together with the inverter model and the time of the event. Ask your installer or Sunways technical support to confirm its meaning and the required checks for that model. Do not assume that the message identifies a particular external cause or requires a component replacement.

Record “E2 Fault” exactly as displayed and contact your installer or Sunways technical support with the inverter model, serial number and any accompanying messages. The correct diagnostic and restart procedures must be identified from the manual for that model.

“GFCI Device Fault” concerns the inverter’s leakage-current detection device. Keep the full alarm name when contacting support so that it is not confused with “GFCI Fault.” Your installer should use the correct model documentation to determine the next checks and whether service is required.

“AC Transducer Fault” concerns the inverter’s AC sensing function. Record the full message and any other alarms, then contact your installer or Sunways technical support. The message alone is not enough to decide which part needs repair or replacement.

“Relay Check Fail” indicates a problem reported during the inverter’s relay check. Ask a qualified installer to investigate using the manual for your exact model. Do not apply a universal voltage threshold or assume that the message proves a particular wiring fault. Include the alarm photo and inverter details in your support request.

“Internal Fan Fault” indicates a reported problem with the hybrid inverter’s internal fan. Record the message and contact your installer or Sunways technical support. Internal inspection and any fan replacement should be performed by qualified service personnel following the model’s service instructions.

“External Fan Fault” indicates a reported problem with the hybrid inverter’s external fan. Note any visible obstruction without opening the equipment or reaching into the fan area. Ask your installer to follow the correct isolation and inspection procedure before deciding whether cleaning or replacement is needed.

“Bus Voltage Hard Fault” is a bus-voltage-related alarm on the hybrid inverter. Record the full wording so that support can distinguish it from other bus voltage messages. Contact your installer or Sunways technical support for the diagnostic procedure that applies to your exact model.

“PV Power Low” indicates low PV power at the hybrid inverter. Check whether sunlight is limited or the array is visibly shaded, without accessing the roof or touching electrical equipment. If the message continues under otherwise suitable conditions, ask your installer to investigate the PV system.

“Bat OV” is a battery-overvoltage message shown by the hybrid inverter. Record both the inverter message and any alarm shown on the battery. Contact your installer with the inverter and battery model details so that the permitted operating range and installation can be checked against their documentation.

“Backup OV” indicates an overvoltage condition reported at the hybrid inverter’s backup output. Note whether backup operation is affected and record any accompanying messages. Ask your installer to check the backup installation using the correct user manual; do not alter its wiring yourself.

“Bus Volt Low” indicates that the hybrid inverter has detected a low internal bus voltage. Record the exact message and operating conditions, then contact your installer or Sunways technical support. The fault name alone does not identify the component or connection responsible.

“Hard Fault” is a general fault message that requires the exact inverter model and any accompanying alarm information to interpret. Send a photo of the display, the serial number and a description of what happened before the message appeared to your installer or Sunways technical support.

“Backup OP” indicates an overload at the hybrid inverter’s backup output. Where safe, switch off non-essential appliances connected to the backup supply using their normal controls. If the message remains, ask your installer to compare the connected loads with the backup limits in the exact model’s documentation.

“Inverter OV” is described here as a backup-output overvoltage alarm. Record the full wording and contact your installer with the inverter model and operating conditions. Ask the installer to confirm the code against the correct manual before diagnosing the backup circuit.

“Inverter OF” is described here as a backup-output overfrequency alarm. Record whether the system was supplying backup loads when it appeared. Your installer or Sunways technical support should confirm the model-specific meaning and next steps before any settings are changed.

“Inverter OC” is described here as a backup-output overcurrent alarm. Record the loads that were operating when it occurred and contact your installer. The installer should confirm the alarm meaning and assess the backup circuit using the documentation for your exact model.

“Phase Order Err” indicates a reported phase-sequence problem. Record the message and ask a qualified installer to verify the installation against the inverter’s wiring instructions. Do not change phase connections or attempt electrical measurements yourself.

“SCI Fault” is an internal-communication-related message on the hybrid inverter. Record any accompanying alarms and contact your installer or Sunways technical support. The model documentation is needed to identify the relevant communication path and diagnostic procedure.

“FLASH Fault” is an internal-storage-related message on the hybrid inverter. Send the exact alarm text, inverter model and serial number to your installer or Sunways technical support. Do not install firmware or use reset instructions intended for a different model.

“Meter Comm Fault” indicates a communication problem between the hybrid inverter and the meter. Record the inverter and meter model details and whether the message followed installation work. Ask your installer to check the communication connection and meter configuration against the relevant manuals.

“Battery Fault” means that the hybrid inverter is reporting a battery-related fault. Check whether the battery also displays an alarm and record that message or indicator pattern without opening the equipment. Provide both product models and the alarm details to your installer or Sunways technical support.

Grid-tied Inverter FAQs

Find the message shown on your inverter below. Fault names and the checks required can vary by model; use the matching user manual when deciding what to do next.

“ISO Over Limitation” indicates that the inverter has detected low insulation resistance. Note whether the message appears during wet weather or after work on the installation. Ask a qualified installer to inspect the relevant wiring and insulation according to the model’s manual. Do not disconnect PV strings or carry out electrical measurements yourself.

“DCI Fault” relates to the DC component detected in the inverter’s AC output. Record the exact message and contact your installer if it persists. Any restart or diagnostic procedure should follow the user manual for your exact model; do not use a restart sequence from a different inverter.

“Grid Frequency Fault” indicates that the detected grid frequency is outside the configured protection range. Record whether the message coincides with a grid disturbance. If it remains or returns, ask your installer to verify the supply and the correct installation-country settings. Changing to a different country profile is not a general troubleshooting step.

“Grid Voltage Fault” indicates that the detected grid voltage is outside the configured protection range. Record the message, the displayed reading and when it occurs. Ask your installer to check the local supply, AC installation and approved settings for your exact model and installation location. Do not change the country profile or widen protection limits to clear the alarm.

“Mains Lost” indicates that the inverter is not detecting the AC grid supply. Check whether there is a power outage at the property and note whether other electrical equipment has also lost power. If the grid supply is available but the message remains, ask your installer to check the AC supply path and connections using the manual for your inverter.

“GFCI Fault” indicates that the inverter has detected excessive leakage current. Record when the alarm appears and whether weather conditions or recent installation work coincide with it. Ask your installer to investigate the insulation and relevant circuits. Weather-related timing alone does not confirm the cause or show that the installation is safe.

“PV Over Voltage” indicates that the inverter has detected a PV input voltage above its permitted limit. Ask your installer to compare the PV string design and measurements with the datasheet and user manual for the exact inverter model. Do not remove panels or disconnect PV connectors yourself.

“Bus Voltage Fault” concerns the inverter’s internal DC bus voltage. The fault message alone does not establish whether the cause is the PV input or an internal issue. Record the message and ask your installer or Sunways technical support to identify the checks required for your exact model.

“Inverter Over Temperature” indicates that the inverter has detected an excessive internal temperature. From a safe position, check whether its ventilation area is visibly obstructed and note the surrounding conditions. Ask your installer to verify the installation clearances and cooling requirements in the correct user manual. Contact support if the alarm persists.

“GFCI Device Fault” concerns the inverter’s leakage-current detection device. Keep the full alarm name when contacting support so that it is not confused with “GFCI Fault.” Your installer should use the correct model documentation to determine the next checks and whether service is required.

“AC Transducer Fault” concerns the inverter’s AC sensing function. Record the full message and any other alarms, then contact your installer or Sunways technical support. The message alone is not enough to decide which part needs repair or replacement.

“Relay Check Fail” indicates a problem reported during the inverter’s relay check. Ask a qualified installer to investigate using the manual for your exact model. Do not apply a universal voltage threshold or assume that the message proves a particular wiring fault. Include the alarm photo and inverter details in your support request.

Record “E2 Fault” exactly as displayed and contact your installer or Sunways technical support with the inverter model, serial number and any accompanying messages. The correct diagnostic and restart procedures must be identified from the manual for that model.

Record “SPI Fault” exactly as displayed, together with the inverter model and the time of the event. Ask your installer or Sunways technical support to confirm its meaning and the required checks for that model. Do not assume that the message identifies a particular external cause or requires a component replacement.

A blank display means that no information is visible on the inverter screen; it does not by itself identify the cause. Note the time, available daylight and whether any indicators are on. Ask your installer to check the supply conditions and connections using the correct model’s manual. Do not open the inverter or measure terminals yourself.

Battery FAQs

Look up battery alarm topics below. Interpret indicator lights using the manual for your exact battery model, and record any related inverter messages when requesting support.

An unexpected SOC change may reflect an issue with the charge estimate or an imbalance between battery modules, rather than a confirmed loss of capacity. Record the SOC before and after the change and any battery alarms. Ask your installer to assess the battery using its model documentation before attempting balancing, charging or software changes.

An overvoltage alarm indicates that the battery has reported a high-voltage condition. Record the exact alarm and indicator pattern, then contact your installer or technical support with the battery model. Use the matching manual to interpret the lights; do not apply an indicator pattern from another battery.

An undervoltage alarm indicates that the battery has reported a low-voltage condition. Record the message, displayed SOC and indicator pattern. Contact your installer for the recovery procedure that applies to the exact battery model; do not attempt a generic forced-charge or reset procedure.

An overtemperature alarm indicates that the battery has reported a temperature above its allowed operating range. Record the alarm and surrounding conditions. Follow the matching manual and contact your installer if the condition persists. Do not assume that the alarm clearing confirms the underlying installation issue is resolved.

An undertemperature alarm indicates that the battery has reported a temperature below its allowed operating range. Record the conditions and consult the matching battery manual. Ask your installer how to restore suitable conditions for that model; do not use an improvised heating method.

An overcurrent alarm indicates that the battery has reported excessive current. Record the alarm, indicator pattern and what the system was doing when it occurred. Ask your installer or technical support to check the battery and connected system against the correct product documentation.

A PCB overtemperature alarm concerns the battery’s circuit-board temperature. Record the exact alarm or light pattern and contact your installer with the battery model. Do not treat this as an interchangeable code for every battery temperature alarm; the correct manual is needed to interpret it.

A precharge error is a reported fault in the battery’s precharge process. Record the message and contact your installer or technical support. Use the battery model and serial number to identify the correct checks; do not repeatedly power-cycle the system or attempt to bypass the process.

A relay error is a relay-related fault reported by the battery. Record the alarm and indicator pattern, then contact your installer or technical support with the battery details. Relay inspection and any replacement require the procedures for the exact model.

A self-test failure means that the battery has reported an unsuccessful internal check. Send the complete alarm information, battery model and serial number to your installer or technical support. The message alone does not identify a specific component for replacement.

Accessories & Wi-Fi FAQs

Find help with smart-meter faults and Wi-Fi connection problems. Have the accessory model and the connected inverter details ready when contacting support.

A smart-meter fault may involve the meter connection or current-transformer (CT) installation. Record the exact message and the meter and inverter models. Ask your installer to check the communication wiring, CT direction and phase matching against the correct diagrams. Do not change CT wiring or add a repeater without confirming the supported installation.

To investigate a Wi-Fi connection problem, first check whether the home network has internet access and record the Wi-Fi module’s indicator state. Confirm that the inverter is operating, then follow the setup guide for your exact module. If it still cannot connect, send the module model, indicator photo and setup error to technical support.

Monitoring & Sunways Cloud FAQs

Find help with Sunways Cloud access, plant information and device alarms. For instructions that depend on the interface, use the guidance for your current app or web version.

First identify whether the problem is an app update or missing plant data. For an update problem, record your phone system, app version and any error message. For missing data, check your internet connection and whether the inverter is operating. If the issue continues, send these details and a screenshot to technical support before removing or reinstalling the app.

Open Sunways Cloud and use the registration option available for your account type. Complete the information and email-verification steps shown on the current registration screen, and review the displayed terms. If registration is unavailable or cannot be completed, contact your installer or technical support with a screenshot of the issue.

Open Sunways Cloud and sign in with the email address and password associated with your account. If you cannot sign in, record the message shown and contact technical support. Do not include your password or verification code in a support request.

After signing in, open the account menu to find the available profile and account-security options. Use the relevant option for the information you want to change. If you cannot find it or the change fails, contact support with your platform version and a description of the issue. Never send your password or verification code.

Select your plant to open its overview. Use the information shown there to review the plant’s current status and generation summary. If information is missing or appears incorrect, send technical support the plant identifier, the time checked and a screenshot so that the display issue can be investigated.

Open your plant and select the relevant inverter’s device-information view. Review the device details and operating information available there. When reporting a problem, identify which device you selected and include its serial number and a screenshot of the relevant information.

Open the plant or device view and select the power or generation display relevant to your question. Check the displayed timestamp and selected time period before interpreting the data. If the information appears out of date, record the last visible update and refer to the guidance above for missing plant data.

Open the relevant device’s history view, choose the operating parameter you want to review and select the time period. Use the resulting chart to investigate that period. If you need support, include the parameter, date range and a screenshot rather than a chart without context.

Open the relevant device’s alarm view and record the alarm text and time. Share these details with your installer or Sunways technical support together with the product model and serial number. If an alarm is no longer displayed, mention when it disappeared; this alone does not explain its cause.

Still Need Help?

If you cannot find your message or the issue continues, contact your installer or Sunways technical support. Include the product model, serial number, installation country, exact fault message, when it occurred and a clear photo or screenshot. For battery or meter issues, include the connected equipment details as well.

Where can I find the user manual for my Sunways product?

Visit Product Documents→ and select the product that matches your equipment. Check the document’s model coverage before following its instructions. If you cannot find the correct manual, contact technical support with the product model and serial number.

What information should I include in a technical support request?

Include the product model and serial number, your installation country, the exact fault message and when it occurred. Add a photo or screenshot and describe any recent changes to the system. Include relevant battery, meter or communication-module details, but do not send account passwords or verification codes.

Where can I find Sunways warranty information?

Visit Warranty & Service Support → to review the available warranty documents. Check the terms relevant to your product before submitting a request, and prepare the product details, purchase documentation and fault information.

Scan to follow Sunways on WeChat

Scan the QR code to follow Sunways on WeChat and get the latest updates on solar inverter products, energy storage solutions, project cases and company news.

Sunways Wechat QR

Get a Solar Solution Quote

Tell us your project needs. Sunways will help you find the right solar inverter, battery or energy storage solution.

Your Contact Information
Project & Product Interest
Inquiry Details