Solar & Battery Storage | For Installers and Distributors
3-8 kW Single-Phase Hybrid Inverters
Sunways STH-3K~8KTL-LS Series
Build a single-phase solar and battery system around the Sunways STH-LS series. Compare model-specific PV inputs, battery current limits and backup output before selecting an inverter for your installation or product range.
- Single-phase hybrid design
- 40-60 V battery voltage range
- 1 or 2 MPPTs, depending on model
- IP66 protection
Compare STH-LS Models
Choose the model by rated output and the requirements of your PV array, battery and backup loads. The maximum battery charge and discharge current varies across the range.
| Model | Rated Grid Output |
MPPTs | Maximum Battery Charge Current |
Maximum Battery Discharge Current |
|---|---|---|---|---|
| STH-3KTL-LSS | 3.00 kW | 1 | 80 A | 80 A |
| STH-3.6KTL-LSS | 3.68 kW | 1 | 80 A | 80 A |
| STH-4KTL-LS | 4.00 kW | 2 | 100 A | 100 A |
| STH-4.6KTL-LS | 4.60 kW | 2 | 100 A | 100 A |
| STH-5KTL-LS | 5.00 kW | 2 | 120 A | 120 A |
| STH-6KTL-LS | 6.00 kW | 2 | 120 A | 120 A |
| STH-7.5KTL-LS | 7.50 kW | 2 | 160 A | 160 A |
| STH-8KTL-LS | 8.00 kW | 2 | 160 A | 160 A |
Select the regional model and grid settings for the installation country. Battery limits and backup loads must be checked against the selected model and the complete system design.
Key Features for Single-Phase Storage Projects
Model-Specific PV Inputs
Low-Voltage Battery Integration
Dedicated Backup Output
IP66 Protection
Options for Off-Grid Expansion
Technical Specifications
| Parameter | STH-LS Series |
|---|---|
| Start-up voltage | 58 V |
| Maximum DC input voltage | 600 V |
| MPPT voltage range | 80–550 V |
| Maximum PV input current | 20 A per listed input |
| Battery voltage range | 40–60 V |
| Battery communication | CAN |
| UPS switching time | <10 ms |
| Maximum efficiency | 97.6% |
| Protection degree | IP66 |
See the model comparison and current datasheet for the limits that vary by model.
Downloads and Product Documents
Review the datasheet, user manual and quick installation guide for the selected product version. For certification enquiries, specify the exact model and installation country.
Single-Phase Hybrid Inverter FAQs
Q1. Is this a single-phase or three-phase inverter?
The STH-LS series on this page is single-phase. If your project requires a three-phase supply, compare the STH-LT series and check the site requirements with your installer.
Q2. Do all models have the same number of MPPTs?
No. The STH-3KTL-LSS and STH-3.6KTL-LSS have 1 MPPT; the other models listed above have 2. Use the model table when planning the PV strings.
Q3. Can I connect any battery within the stated voltage range?
Battery voltage is one selection requirement. Send the battery model and BMS communication details to Sunways to check compatibility with the selected inverter and product version.
Q4. What should I check for backup operation?
Check the model’s rated backup output, peak output conditions and intended loads. The datasheet’s switching-time value does not determine how long the battery can power those loads.
Q5. How do I request a distributor or project quote?
Send your country, preferred models and order quantity. For a specific installation, add the PV, battery and backup-load requirements so the enquiry includes the information needed for model selection.
Request a Single-Phase Hybrid Inverter Quote
Tell us which STH-LS models you are considering, where the products will be installed and how many units you need. Include battery and backup-load details for a project enquiry.